adi-insite-us
ADI US App
ADI Global Distribution
ADI a Resideo company
menu
Altronix AL600ACMCB220 Access Power Controller with Power Supply/Charger, 8 PTC Class 2 Relay Outputs, 12/24VDC at 6A, FAI, 220VAC, BC400 Enclosure

Altronix AL600ACMCB220 Access Power Controller with Power Supply Charger, PTC Class Relay Outputs, 12/24VDC at 6A, FAI, 220VAC, BC400 Enclosure

AL600ACMCB220|AX-AL60ACMCB

Altronix AL600ACMCB220 Access Power Controller with Power Supply Charger, PTC Class Relay Outputs, 12/24VDC at 6A, FAI, 220VAC, BC400 Enclosure

AL600ACMCB220|AX-AL60ACMCB

Sign In for Dealer Pricing

Become an ADI Customer
Altronix AL600ACMCB220 Access Power Controller with Power Supply/Charger, 8 PTC Class 2 Relay Outputs, 12/24VDC at 6A, FAI, 220VAC, BC400 Enclosure
Altronix

Altronix AL600ACMCB220 Access Power Controller with Power Supply Charger, PTC Class Relay Outputs, 12/24VDC at 6A, FAI, 220VAC, BC400 Enclosure

AL600ACMCB220 | AX-AL60ACMCB

Please sign in to view pricing and availability and to add to cart.

Overview
Specifications
Documents

Product Overview

Introducing the Altronix AL600ACMCB220 Access Power Controller, a versatile solution for your access control needs. This unit efficiently transforms a standard 220VAC input into eight independently managed outputs, delivering 12VDC or 24VDC with a robust 6A continuous supply. Designed for seamless integration with various access control devices, it supports both Fail-Safe and Fail-Secure modes. The FACP Interface enhances safety with emergency egress and alarm monitoring capabilities. With options for single or dual power sources, this power supply/charger is perfect for any security setup. Elevate your security system today with the Altronix AL600ACMCB220!

Main Features

  • Eight (8) independently controlled Fail-Safe and/or Fail-Secure power outputs.
  • Eight (8) auxiliary power outputs (unswitched)
  • Output PTCs are rated at 2.5A
  • Filtered and electronically regulated outputs.
  • Supervision: - AC Fail - Battery Fail and Battery Presence.
  • Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the eight (8) outputs.
  • Alarm output relay indicates that FACP input is triggered.
  • Fire Alarm disconnect input options: a) Normally open (NO) or normally closed (NC) dry contact input b) Polarity reversal input from FACP signaling circuit.
  • Built-in charger for sealed lead acid or gel type batteries.
  • Instantaneous transfer to stand-by batteries

General Information

Name: Altronix AL600ACMCB220 Access Power Controller with Power Supply Charger, PTC Class Relay Outputs, 12/24VDC at 6A, FAI, 220VAC, BC400 Enclosure
Category: Altronix, Batteries & Power Supplies, Power Supplies & Boards, Access Power Controllers
UPC Code: 782239942848
Country of Origin: United States. Country of origin is subject to change.

Specifications

Product Documents and Resources